MSG4000: Mass Spect Gold Human Serum, Ultra-Low Hormones & Steroids

from $412.00

Human serum that has been specially processed to reduce the levels of endogenous hormones and steroids to exceedingly low concentrations. This type of serum is ideal for ultra-sensitive immunoassay and mass spectrometry applications.

Description:

This material has been tested at the donor level and found negative or non-reactive for HIV 1/2 Antibody, HBsAg, HCV Antibody, HIV-1 (NAT) and HCV (NAT) by FDA Approved Methods

Source: Human Serum, Defibrinated from Plasma

Country of Origin: United States

Filtration: 0.1 µm

Storage Temp: -20°C

Definition: Defined as -15°C to -30°C

Request a quote or general inquiry for bulk pricing, COA, or specification sheet.

Volume:
Quantity:
Add To Quote

Human serum that has been specially processed to reduce the levels of endogenous hormones and steroids to exceedingly low concentrations. This type of serum is ideal for ultra-sensitive immunoassay and mass spectrometry applications.

Description:

This material has been tested at the donor level and found negative or non-reactive for HIV 1/2 Antibody, HBsAg, HCV Antibody, HIV-1 (NAT) and HCV (NAT) by FDA Approved Methods

Source: Human Serum, Defibrinated from Plasma

Country of Origin: United States

Filtration: 0.1 µm

Storage Temp: -20°C

Definition: Defined as -15°C to -30°C

Request a quote or general inquiry for bulk pricing, COA, or specification sheet.

Human serum that has been specially processed to reduce the levels of endogenous hormones and steroids to exceedingly low concentrations. This type of serum is ideal for ultra-sensitive immunoassay and mass spectrometry applications.

Description:

This material has been tested at the donor level and found negative or non-reactive for HIV 1/2 Antibody, HBsAg, HCV Antibody, HIV-1 (NAT) and HCV (NAT) by FDA Approved Methods

Source: Human Serum, Defibrinated from Plasma

Country of Origin: United States

Filtration: 0.1 µm

Storage Temp: -20°C

Definition: Defined as -15°C to -30°C

Request a quote or general inquiry for bulk pricing, COA, or specification sheet.

  • The study presents a mass spectrometry-based method for precise measurement of thyroglobulin (Tg) in serum, offering a more sensitive alternative to traditional immunoassays. Using a monoclonal antibody for peptide purification and DMSO for enhanced detection, the method achieved a lower limit of quantification of 0.15 ng/mL.

    The MSG4000 human serum pool was utilized to create a "Husky Ref" reference material, ensuring assay consistency across laboratories. This advancement aims to standardize Tg testing, particularly for patients with interfering autoantibodies.

    For a detailed look at the study's findings and the specific use of MSG4000 serum, you can read the full article at ScienceDirect.

  • The research paper describes a clinical research method using UPLC-MS/MS for analyzing serum estrogens, focusing on estradiol (E2) and estrone (E1), without requiring derivatization and utilizing only 250 µL of sample.

    MSG4000 stripped serum was employed as a surrogate matrix to prepare calibrator and quality control samples, which are key to the method's sensitivity and precision. With a lower limit of quantification of 3 pg/mL for E2 and 2 pg/mL for E1, the developed assay demonstrated excellent precision, accuracy, and linearity, effectively differentiating between a blank sample and one spiked with 1 pg/mL of E2.

    The study highlights the method's capability to achieve robust results with minimal sample volume and without significant endogenous interference.

    For a detailed look at the study's findings and the specific use of MSG4000 serum, you can read the full article at Waters.

  • The study aimed to compare the performance of four different clinically validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods for testosterone determination by conducting interlaboratory comparisons using human serum samples.

    The double charcoal-stripped human serum (MSG4000) was employed as a matrix for calibration and quality control in these assays. The study aimed to assess how well different LC-MS/MS methods correlate and harmonize in testosterone quantification, which is important for ensuring accurate and reliable clinical testing across different laboratories.

    For a detailed look at the study's findings and the specific use of MSG4000 serum, you can read the full article at PMC.

  • The research paper investigates plasma retinoid concentrations in pregnant women and compares them with levels ≥3 months postpartum. The study found that plasma retinol, retinol binding protein 4 (RBP4), transthyretin, and albumin concentrations decreased during pregnancy but returned to baseline postpartum.

    Golden West’s Double Charcoal Stripped Serum (MSG4000) was used as a surrogate matrix for creating calibration and quality control (QC) samples for the quantification of estrogens E2 and E1. This facilitated the assay's capability to distinguish between E2 levels in blank samples and low concentration spiked samples, thus demonstrating significant changes in maternal retinoid concentrations due to pregnancy.

    For a detailed look at the study's findings and the specific use of MSG4000 serum, you can read the full article at MDPI.

  • This study examines the variations in retinoid concentrations across pregnancy and after childbirth. Using liquid chromatography-tandem mass spectrometry, the study observed significant fluctuations in the levels of retinoids like all-trans-retinoic acid (atRA), 13-cis-retinoic acid (13-cis RA), and their oxidative metabolites. The researchers discovered a decrease in 13-cis RA across pregnancy with an increase in levels post-delivery and an increase in atRA concentrations mid-pregnancy.

    Golden West's MSG4000 serum was utilized as the matrix for the calibration standards and as a surrogate matrix for quality control samples in the quantification process of retinoids. This study provides new insights into the changes in retinoid homeostasis in pregnant women.

    For a detailed look at the study's findings and the specific use of MSG4000 serum, you can read the full article at PLoS One

  • This study investigates the relationship between Cytochrome P450 2D6 (CYP2D6) enzyme activity and plasma bile acid concentrations during and after pregnancy. The study found that plasma concentrations of taurocholic acid were positively correlated with the activity of CYP2D6, implying that variations in bile acid levels during pregnancy may influence the enzyme's activity.

    Golden West's MSG4000 serum was used to create calibration standards and quality control samples for measuring bile acids, facilitating the analysis of their systemic concentrations in pregnant women. The study provides evidence that alterations in the plasma bile acid metabolome during pregnancy may affect CYP2D6 activity, which is important for the metabolism of many drugs.

    For a detailed look at the study's findings and the specific use of MSG4000 serum, you can read the full article at ASPET.

MSG3100: Mass Spect Gold Human Serum, Ultra-Low Testosterone, Lipid Free
$556.00
SP2070: Human Serum, Off the Clot, Double Charcoal Treated & Delipidized
$0.00
SP1070: Human Serum Double Charcoal Treated and Delipidized from Defibrinated Plasma
from $215.00
MSG10000: Mass Spect Gold Thyroid Stimulating Hormone Receptor, Antibody Negative
$0.00
MSG3000: Mass Spect Gold Human Serum, Ultra-Low Hormones & Steroids, Lipid Free
from $371.00